Place of use
These cables are used in transmission of VGA video signals in multipurpose media applicatios. They have high resolution and low attenuation values. This type of cables is halogen-free, has flame-retarder and low smoke density.
Inner Conductor | 7x0,16 mmØ Electrolytic Stranded Tinned Copper |
Dielectric | 2,10 mmØ Foam Polyethylene |
1.Screen | %100 Coverage Tinned Copper Wrap |
2.Screen | %100 Coverage AL-PES Tape |
Coaxial Sheath | 3,05 mmØ PVC (Red, Green, Blue,Black,White) |
3.Screen | %100 Coverage AL-PES Tape |
Drain Wire | 7x0,25 mmØ Electrolytic Stranded Tinned Copper |
Outer Sheath | 10,50 mmØ HFFR Compaund, RAL 7001 Gray |
Product Code | Dimension and Weights | Electrical Properties | |||||||||
Nominal Cross Section | Overall Diemeter ( ~ ) |
Net Weight ( ~ ) |
Standart Lenght | Max. Dc Conductor Resistance at 20◦ C | Current Carrying Capacity | ||||||
In Ground at 20° C | On Air at 30° C |
MUTUAL CAPACITANCE | VELOCITY OF PROPAGATION | OPERATING VOLTAGE | IMPEDANCE | BENDING RADIUS | TEMPERATURE RANGE |
57 pF/m | 78 % | 1 kV | 75±3 Ω | 15x D mm | -30ºC+70ºC |
FLAME RETARDANT TEST | SMOKE DENSITY TEST | TEST ON CORROSIVENESS OF COMBUSTION GASES | HALOGEN FREE TEST | FLAME PROPOGATION TEST |
IEC 60332-1-2 VDE 0482-332-1-2 EN 60332-1-2 | IEC 61034-2 VDE 0482-1034-2 EN 61034-2 | IEC 60754-2 VDE 0482-267-2-3 EN 50267-2-3 | IEC 60754-1 VDE 0482-267-2-1 EN 50267-2-1 | IEC 60332-3-25 VDE 0482-332-3-25 EN 60332-3-25 |